TLC Pharmaceutical Standards headquarters at 130 Pony Drive, Newmarket, Ontario
Newmarket, Ontario · Serving labs worldwide since 2007

Your trusted source for Reference Standards, manufactured and certified in-house

Manufactured, characterized, and certified in our purpose-built Canadian facility, TLC Pharmaceutical Standards delivers complex organic reference standards trusted by pharmaceutical and biotechnology laboratories. Available from stock or made to order, every standard is supplied with a comprehensive Certificate of Analysis.

COA with every compound Synthesis & analytical labs in-house
01 — News

The latest from the lab.

May 18, 2026New product

New reference standard: Tacrolimus-13C-d4

Following customer feedback, we are pleased to announce the successful development of Tacrolimus-13C-d4, a new stable isotope-labeled reference standard designed to provide a larger mass shift for improved performance as an internal standard.

Read more →

While our previously developed Tacrolimus-13C-d2 standard was successfully used in a range of analytical applications, several clients working with this large and structurally complex molecule indicated that a greater mass difference was preferred for highly sensitive LC-MS/MS methods. In response, our laboratory rapidly adapted to this market need and developed Tacrolimus-13C-d4—demonstrating our flexibility and commitment to delivering reference standards aligned with evolving customer requirements.

Tacrolimus-13C-d4 has been produced with high isotopic enrichment and excellent chemical purity as detailed in its COA, making it well suited for analytical applications including:

  • LC-MS/MS quantitative analysis
  • Bioanalytical method development and validation
  • Pharmacokinetic and therapeutic drug monitoring studies
  • GLP-compliant analytical workflows

The development of a highly enriched multi-labeled tacrolimus standard presents significant synthetic and analytical challenges, and materials of this type can be difficult to source at consistently high quality.

Please contact TLC for availability and quotation.

May 10, 2026Event

CPHI Shanghai 2026

We’re pleased to share that TLC will be exhibiting at CPHI Shanghai 2026!

Read more →

From June 16-18, visit us at booth E2G26 to learn more about our latest developments, discuss industry trends, and explore new collaboration opportunities in the pharmaceutical and healthcare sectors.

Our team looks forward to connecting with partners and professionals from across the globe and sharing how TLC continues to support innovation and growth in the industry.

See you in Shanghai!

Apr 25, 2026New product

New reference standard: Tretinoin-d6

We are pleased to announce the successful development of Tretinoin-d6, a high-quality stable isotope-labeled (SIL) reference standard developed to address the limitations commonly seen with lower-labeled alternatives on the market.

Read more →

Tretinoin (all-trans retinoic acid), CAS No. 302-79-4 is widely used in pharmaceutical, dermatological, and analytical research. This d6-labeled analog is designed to support LC-MS/MS method development, validation, and quantitative analysis where a robust internal standard is critical.

Previously available Tretinoin-d5 materials have demonstrated lower isotopic enrichment and residual unlabeled content, which can create potential interference challenges for end users. To overcome this, TLC developed a superior d6-labeled version by directly introducing six deuterium atoms onto two methyl groups using deuterated reagents, resulting in stronger label stability and improved analytical performance.

Our final product achieves:

  • 99.5% deuterium enrichment
  • No detectable d0 content
  • Stable deuterium incorporation resistant to label loss during testing
  • Improved suitability as an internal standard for sensitive LC-MS/MS applications
  • COA available here: COA

The development of Tretinoin-d6 required a highly complex synthetic route involving more than 15 steps. Both intermediates and the final product are highly unstable and sensitive to light and temperature, requiring strict oxygen-free, light-free, and low-temperature conditions throughout reaction, workup, and purification processes.

Due to the technical difficulty of synthesis and the exceptional isotopic quality achieved, Tretinoin-d6 represents a significant advancement for laboratories requiring dependable SIL reference standards.

Please contact TLC for availability and quotation.

TLC analysts working at HPLC instruments in the analytical lab
Inside the lab

Synthesis and analytical labs, under one roof.

Every stage—from route development to synthesis, characterization, and certification—is performed in the same facility, ensuring consistency, traceability, and quality at every step.

HPLC · NMR · MS
Comprehensive characterization
ISO/IEC 17025 · ISO 17034
Accredited testing & reference material production
ISO 9001
Quality management system
02 — Why TLC

The TLC advantage.

Where others stop, we start.

Organic synthesis experts in challenging and high-uncertainty routes.

A COA for every compound

Complete documentation, every product, no exceptions.

When quality and speed matter most

The highest standards with rapid delivery timelines

Full in-house facilities

Synthesis and analytical labs under one roof for fully integrated development.

A comprehensive inventory of available standards

24,000+ compounds in stock, expanding by ~2,000 annually.

RFQ Basket 0